<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-08 02-58-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 49 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 3.1 kHz -86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
18 kHz 44 kHz 18884 0,1853
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,66 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 2:58, 8.05.2024
RT
"Ceske pisnicky ktere si zazpivate "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 44 kHz MIN: 18 kHz % above 77 kHz: 0,1853 Acquired: 2024/05/08 2:58:48 Total samples: 18884 Equivalent time: 0:15:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -0,3 dBr MIN: -1,2 dBr AVE: -0,66 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2024/05/08 2:58:48) 02:44 02:46 02:48 02:50 02:52 02:54 02:56 02:58 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality